VadaTech Incorporated • 198 N. Gibson Rd, Henderson, NV 89014 • Tel: (702) 896-3337 • Fax (702) 896-0332 Email: info@vadatech.com • www.vadatech.com UTC023 / UTC023C – DC Power Module, 241W or 460W, Double Module
The VadaTech UTC023 is a 241/460W power module for use in a µTCA chassis. The power module runs at 84% efficiency when running at maximum load. This results in 200/400W output (available to the system). It is fully compliant with the MicroTCA.0 and MicroTCA.1 specifications; including dual-redundant I2C buses (IPMB-0). The UTC023 is fully redundant when used in conjunction with a second instance of the module. It provides power to the twelve slots, two MCHs (MicroTCA Carrier Hubs) as well as the CUs. Multiple temperature sensors are included on-board to monitor for over-temp conditions within the module. The current is continuously measured for each of the modules and reported to MCH for any fault. The firmware is upgradable via HPM. The module is available in conduction cooled variant for harsh environments. • Double module, full-size per AMC.0 • 10 to 36 VDC input for 241W option and 18 to 36 VDC input for 460W option • Support for power module redundancy • Dual IPMI bus • 32-bit RISC processor • Two banks of 256K flash for redundancy • Field upgradable • IPMI 2.0 compliant • HPM.1 compliant • Modules can be turned on without the presence of an MCH • Menu driven software for ease of configuration • Current measure for each module • External as well as internal WDT
241W or 460W DC Power Module
Benefits of Choosing VadaTech • Very low ripple voltage • Support for power module redundancy • Efficient re-use of existing designs/components reduce costs • Electrical, mechanical, software and system-level expertise in house • Full ecosystem of front and rear boards, enclosures, speciality modules, and test/dev product from one source
KEY FEATURES
Doc No. 4FM737-12 Rev 01 Version 1.0 – AUG/16 UTC023 / UTC023C – DC Power Module, 241W or 460W, Double Module info@vadatech.com www.vadatech.com
Figure 1: UTC023 Conduction Cooled Assembly
Figure 2: UTC023 without Cover
Figure 3: UTC023 without Cover (isometric)
Doc No. 4FM737-12 Rev 01 Version 1.0 – AUG/16 UTC023 / UTC023C – DC Power Module, 241W or 460W, Double Module info@vadatech.com www.vadatech.com
IPMI FUNCTIONALITY The UTC023 is IPMI 2.0 and HPM.1 compliant with optional IPMI commands including warm/cold reset, re-arm sensor events, get device GUID, and get/set the hysteresis, threshold, and/or sensor event enable. The PMs follow the ATCA specification in fail-over for redundant IPMB-0 and FRU LED control. The units also have power channel control, get power channel status, PM reset, get PM status, and PM heartbeat. Temperature and current sensors are also included. UTC023 BLOCK DIAGRAM LEDsCapCapMicro USBFPGAManagement and Payload Power ControlCurrent SensorsVoltage SensorsTempSensorsPower ConverterManagement Controller+12 V+3.3 VIPMI RS-232
Figure 4: Block Diagram – Air Cooled Version
Figure 5: UTC023 Front Panel View
Doc No. 4FM737-12 Rev 01 Version 1.0 – AUG/16 UTC023 / UTC023C – DC Power Module, 241W or 460W, Double Module info@vadatech.com www.vadatech.com
UTC023C BLOCK DIAGRAM LEDsCapCapMicro USBFPGAManagement and Payload Power ControlCurrent SensorsVoltage SensorsTempSensorsPower ConverterManagement ControllerIPMIRS-232+12 V+3.3 V
Figure 6: Block Diagram – Conduction Cooled Version
Doc No. 4FM737-12 Rev 01 Version 1.0 – AUG/16 UTC023 / UTC023C – DC Power Module, 241W or 460W, Double Module info@vadatech.com www.vadatech.com SPECIFICATIONS
Architecture Physical Dimensions Width: 5.85” (148.5 mm) Depth 7.11” (180.6 mm) Type AMC Power Module Intelligent power controller for µTCA chassis Standards Module Management IPMI IPMI version 2.0 AMC PICMG AMC.0 Revision 1.0 (AdvancedMC) µTCA PICMG MicroTCA.0 Revision 1.0 HPM HPM.1 Revision 1.0
Power UTC023 241 W, input supply: 10 to 36 VDC 460 W, input supply: 18 to 36 VDC Environmental Temperature Operating Temperature: -5° to 55°C industrial and military versions also available (See environmental spec sheet) Storage Temperature: –40° to +85°C Vibration 1G, 5 to 500Hz on each axis Shock 30Gs on each axis Relative Humidity 5 to 95 per cent, non-condensing Front Panel External Interface RS-232 front panel access LEDs IPMI management control: blue, red, amber, green and fuse indicator for each input rail Mechanical Hot swap handle Temperature Sensor Multiple temperature sensors on-board Other MTBF MIL Hand book 217-F @ TBD Hrs Certifications Designed to meet FCC, CE and UL certifications where applicable Standards VadaTech is certified to both the ISO9001:2000 and AS9100B:2004 standards Compliance RoHS and NEBS Warranty Two (2) years
INTEGRATION SERVICES AND APPLICATION-READY PLATFORMS VadaTech has a full ecosystem of ATCA and μTCA products including chassis platforms, shelf managers, AMC modules, Switch and Payload Boards, Rear Transition Modules (RTM), Power Modules, and more. The company also offers integration services as well as pre-configured Application-Ready Platforms. Please contact VadaTech Sales for more information. Trademarks and Disclaimer The VadaTech logo is a registered trademark of VadaTech, Inc. Other registered trademarks are the property of their respective owners. AdvancedTCA™ and the AdvancedMC™ logo are trademarks of the PCI Industrial Computers Manufacturers Group. All rights reserved. Specification subject to change without notice.
Doc No. 4FM737-12 Rev 01 Version 1.0 – AUG/16 UTC023 / UTC023C – DC Power Module, 241W or 460W, Double Module info@vadatech.com www.vadatech.com ORDERING OPTIONS UTC023 – A0C – 000 – 00J
UTC023C – A0C – 000 – 00J
A = Power 1 = 241W (input voltage 10 to 36V) 2 = 460W (input voltage 18 to 36V) J = Temperature Range and Coating 0 = Commercial (–5° to +45° C), No coating 1 = Commercial (–5° to +45° C), Humiseal 1A33 Polyurethane 2 = Commercial (–5° to +45° C),Humiseal 1B31 Acrylic 3 = Reserved 4 = Industrial (–20° to +70° C), Humiseal 1A33 Polyurethane 5 = Industrial (–20° to +70° C), Humiseal 1B31 Acrylic 6 = Military (–40° to +85° C), Humiseal 1A33 Polyurethane 7 = Military (–40° to +85° C), Humiseal 1B31 Acrylic
C = Front Panel 1 = Reserved 2 = Reserved 3 = Full-size 4 = Reserved 5 = Reserved 6 = Full-size, MTCA.1 (captive screw)
A = Power 1 = 241W (input voltage 10 to 36 VDC) 2 = 460W (input voltage 18 to 36 VDC) J = Temperature Range and Coating ** 0 = Commercial (–5° to +45° C), No coating 1 = Commercial (–5° to +45° C), Humiseal 1A33 Polyurethane 2 = Commercial (–5° to +45° C),Humiseal 1B31 Acrylic 3 = Reserved 4 = Industrial (–20° to +70° C), Humiseal 1A33 Polyurethane 5 = Industrial (–20° to +70° C), Humiseal 1B31 Acrylic 6 = Military (–40° to +85° C), Humiseal 1A33 Polyurethane 7 = Military (–40° to +85° C), Humiseal 1B31 Acrylic C = Ruggedization Level* 0 = None 1 = Contact Vadatech 2 = Contact Vadatech 3 = Contact Vadatech
* Ruggedization level is per the uTCA.2 and uTCA.3 specification ** Edge of module
Doc No. 4FM737-12 Rev 01 Version 1.0 – AUG/16 UTC023 / UTC023C – DC Power Module, 241W or 460W, Double Module info@vadatech.com www.vadatech.com RELATED PRODUCTS
8U MTCA.4 Chassis Platform 12 AMCs UTC004 Gen 3 MCH AMC720 Processor AMC
CONTACT US
VadaTech Corporate Office 198 N. Gibson Rd, Henderson, NV 89014 Email: info@vadatech.com Telephone: +1 702 896-3337 Fax: +1 702 896-0332
Asia Pacific Sales Office 7th Floor, No. 2, Wenhu Street, Neihu District, Taipei 114,Taiwan Email: info@vadatech.com Telephone: +886-2-2627-7655 Fax: +886-2-2627-7792
VadaTech European Sales Office VadaTech House, Bulls Copse Road, Southampton, SO40 9LR Email: info@vadatech.com Telephone: +44 2380 016403